Secured Trading Service

Flyback High Voltage PCB Electrical Current Power Transformer Ep10

Hangzhou Udwells Technology Co., Ltd.
  • Audited Supplier
  • 2 yrs

Contact Supplier

Product Highlights

  • Wide Power Range: Output power spans from 0.3VA to 2000VA across multiple EI and Toroidal core models.
  • Customizable Installation: Supports vertical, horizontal, with base, or with cover installation methods.
  • Premium Materials: Uses new high-grade silicon steel sheets and 100% pure copper wire.
  • Comprehensive Testing: 100% factory testing including Hi-Pot, inter-winding, and load tests.
  • Shielding Option: Optional copper foil shielding layer to suppress electromagnetic interference.
  • ISO9001 Certified: Manufacturing process meets ISO9001 quality management standards.
  • Flexible Customization: Full customization available based on samples, designs, or specific requirements.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Flyback High Voltage PCB Electrical Current Power Transformer Ep10

Flyback High Voltage PCB Electrical Current Power Transformer Ep10
Flyback High Voltage PCB Electrical Current Power Transformer Ep10 pictures & photos
Flyback High Voltage PCB Electrical Current Power Transformer Ep10
Flyback High Voltage PCB Electrical Current Power Transformer Ep10 pictures & photos
Flyback High Voltage PCB Electrical Current Power Transformer Ep10
Flyback High Voltage PCB Electrical Current Power Transformer Ep10 pictures & photos
Flyback High Voltage PCB Electrical Current Power Transformer Ep10
Flyback High Voltage PCB Electrical Current Power Transformer Ep10 pictures & photos
Flyback High Voltage PCB Electrical Current Power Transformer Ep10
Flyback High Voltage PCB Electrical Current Power Transformer Ep10 pictures & photos
Flyback High Voltage PCB Electrical Current Power Transformer Ep10
Flyback High Voltage PCB Electrical Current Power Transformer Ep10 pictures & photos
Flyback High Voltage PCB Electrical Current Power Transformer Ep10
  • Flyback High Voltage PCB Electrical Current Power Transformer Ep10
  • Flyback High Voltage PCB Electrical Current Power Transformer Ep10
    Flyback High Voltage PCB Electrical Current Power Transformer Ep10
  • Flyback High Voltage PCB Electrical Current Power Transformer Ep10
    Flyback High Voltage PCB Electrical Current Power Transformer Ep10
  • Flyback High Voltage PCB Electrical Current Power Transformer Ep10
    Flyback High Voltage PCB Electrical Current Power Transformer Ep10
  • Flyback High Voltage PCB Electrical Current Power Transformer Ep10
    Flyback High Voltage PCB Electrical Current Power Transformer Ep10
  • Flyback High Voltage PCB Electrical Current Power Transformer Ep10
    Flyback High Voltage PCB Electrical Current Power Transformer Ep10
  • Flyback High Voltage PCB Electrical Current Power Transformer Ep10
    Flyback High Voltage PCB Electrical Current Power Transformer Ep10

Find Similar Products

Product Description

Flyback High Voltage PCB Electrical Current Power Transformer Ep10
Please click bellow CONTACT US image for more information and quotation.

Flyback High Voltage PCB Electrical Current Power Transformer Ep10
Flyback High Voltage PCB Electrical Current Power Transformer Ep10
Specification
Output Power
Size(unit:mm)
Install PIC
A
B
C
D
E
F
EI-28x11.5
0.3VA-1.8VA
29. 5
40.0
49.0
25.4
27.0
Φ3.5x5.0
A
27.0
38.0
46.5
25.4
30.0
Φ3.5x5.0
B
EI-35x11.5
0.8VA-2.1VA
36.5
45.0
63.0
29.8
31.5
Φ3.5x5.0
A
31.5
40.0
58.0
29.8
37.0
Φ3.5x5.0
B
El-35x13.5
1.0VA-2.7VA
36.7
45.0
55.0
33.2
31.7
Φ3.5x5.0
A
31.0
40.0
50.0
33.2
37.3
Φ3.5x5.0
B
El-35x15.5
1.5VA-3.5VA
37.0
46.0
55.0
34.2
33.0
Φ3.5x6.5
A
31.0
40.0
50.0
34.2
37.5
Φ3.5x6.5
B
El-35x17.5
2.5VA-4.5VA
37.0
46.0
55.0
36.5
33.0
Φ3.5x6.5
A
31.0
40.0
50.0
36.5
37.5
Φ3.5x6.5
B
El-41x16.5
2.0VA-4.5VA
42.7
53.0
62.0
36.5
36.0
Φ4.0x6.5
A
35.0
46.0
55.0
36.5
43.2
Φ4.0x6.5
B
El-41x20.5
3.0VA-6.0VA
42.7
52.5
62.5
41.2
35.5
Φ4.0x6.5
A
34.5
46.0
56.0
41.2
43.0
Φ4.0x6.5
B
El-41x24.5
5.0VA-8.5VA
42.7
53.0
62.3
49.0
36.0
Φ4.0x6.5
A
34.5
46.0
57.0
49.0
43.0
Φ4.0x6.5
B
El-41x26.5
6.0VA-10.0VA
42.7
53.0
62.3
52.0
36.0
Φ4.0x6.5
A
34.5
46.0
57.0
52.0
43.2
Φ4.0x6.5
B
El-48x20.5
6.0VA-10.0VA
49.7
61.0
69.5
40.0
43.5
Φ4.0x7.5
A
42.0
53.0
63.5
40.0
51.0
Φ4.0x7.5
B
El-48x25.5
10.0VA-15.0VA
50.0
61.0
70.0
42.0
44.0
Φ4.0x7.0
A
42.0
53.0
63.5
42.0
51.0
Φ4.0x7.0
B
El-48x30.0
14.0VA-20.0VA
49.7
61.0
73.0
54.4
43.5
Φ4.0x7.0
A
42.0
53.0
63.0
54.4
51.0
Φ4.0x7.0
B
El-48x35.0
16.0VA-25.0VA
50.0
61.0
74.0
58.5
43.8
Φ4.0x7.0
A
42.0
53.0
65.0
58.5
51.0
Φ4.0x7.0
B
El-54x24.0
12.0VA-17.0VA
56.0
72.0
86.6
49.4
46.8
Φ4.0x7.0
A
45.0
62.0
75.6
49.4
58.0
Φ4.0x7.0
B
El-54x28.0
18.0VA-25.0VA
56.0
72.0
86.0
49.4
48.5
Φ4.0x7.0
A
45.0
62.0
76.0
49.4
58.0
Φ4.0x7.0
B
El-54x30.0
20.0VA-27.0VA
56.0
72.0
86.2
49.8
47.0
Φ4.0x7.0
A
45.0
62.0
76.0
49.8
58.0
Φ4.0x7.0
B
El-57x19.0
8.0VA-12.0VA
59.0
71.0
83.5
41.0
50.5
Φ5.0x8.0
A
50.0
62.0
77.6
41.0
61.0
Φ5.0x8.0
B
El-57x24.5
12.0VA-20.0VA
59.5
71.0
85.6
49.8
49.6
Φ5.0x8.0
A
50.1
62.0
73.5
49.8
61.0
Φ5.0x8.0
B
El-57x30.0
El-57x30.0
59.0
71.0
85.6
52.7
50.4
Φ5.0x8.0
A
49.9
62.0
77.6
52.7
60.0
Φ5.0x8.0
B
El-57x35.0
30.0VA-38.0VA
59.5
71.0
83.5
59.0
52.0
Φ5.0x8.0
A
49.8
62.0
73.5
59.0
61.0
Φ5.0x8.0
B
El-57x40.0
33.0VA-43.0VA
59.5
71.0
83.5
64.0
52.0
Φ5.0x8.0
A
49.8
62.0
73.5
64.0
61.0
Φ5.0x8.0
B
EI-60x25.0
16.0VA-22.0VA
62.2
72.0
83.0
50.0
53.0
Φ5.0x8.0
A
51.0
62.0
74.5
50.0
63.3
Φ5.0x8.0
B
El-60x30.0
22.0VA-33.0VA
62.2
72.0
84.0
53.0
54.2
Φ5.0x8.0
A
51.5
62.0
75.0
53.0
63.5
Φ5.0x8.0
B
El-66x28.0
22.0VA-30.0VA
68.2
82.0
98.0
56.0
58.3
Φ5.0x8.0
A
58.0
71.0
83.6
56.0
70.4
Φ5.0x8.0
B
El-66x32.0
33.0VA-40.0VA
68.2
82.0
94.3
60.0
58.3
Φ5.0x8.0
A
58.1
71.0
84.0
60.0
70.0
Φ5.0x8.0
B
El-66x36.0
40.0VA-55.0VA
68.2
82.0
98.5
65.0
57.8
Φ5.0x8.0
A
58.0
71.0
83.5
65.0
71.0
Φ5.0x8.0
B
El-66x40.0
55.0VA-65.0VA
68.2
81.0
94.0
75.0
58.0
Φ5.0x8.0
A
58.0
72.0
83.5
75.0
71.0
Φ5.0x8.0
B
El-66x45.0
65.0VA-80.0VA
68.2
82.0
93.0
80.0
58.0
Φ5.0x8.0
A
58.1
71.0
82.5
80.0
72.0
Φ5.0x8.0
B
El-76x35.0
35.0VA-65.0VA
78.5
90.0
101.0
65.0
67.5
Φ5.0x8.0
A
66.5
81.0
95.0
50.0
80.5
Φ5.0x8.0
B
El-76x40.0
55.0VA-80.0VA
79.0
92.0
104.0
70.0
66.9
Φ5.0x8.0
A
66.5
81.0
95.0
70.0
81.0
Φ5.0x8.0
B
El-76x42.5
70.0VA-100.0VA
79.0
92.0
105.0
75.0
68.0
Φ5.0x8.0
A
66.5
81.0
95.0
75.0
81.0
Φ5.0x8.0
B
Flyback High Voltage PCB Electrical Current Power Transformer Ep10
Specification
Output power
Size(unit:mm)
Install PIC
A
B1
B2
C
D
E
F
EI-76x56.0
90.0VA-150VA
76.0
64.0
74.0
86.0
95.0
69.0
Φ5.0x8.0
C
63.5
50.5
74.0
86.0
95.0
78.0
Φ5.0x8.0
D
EI-76x66.0
120VA-190VA
76.0
64.0
84.0
96.0
105.0
69.0
Φ5.0x8.0
C
63.5
50.5
84.0
96.0
105.0
78.0
Φ5.0x8.0
D
EI-86x43.0
70.0VA-120VA
86.0
71.0
68.0
83.0
75.0
71.5
Φ5.0x8.0
C
71.5
57.0
68.0
83.0
75.0
87.0
Φ5.0x8.0
D
EI-86x45.0
110VA-150VA
86.0
71.0
70.0
85.0
80.0
72.0
Φ5.0x8.0
C
71.5
57.0
70.0
85.0
80.0
87.0
Φ5.0x8.0
D
EI-86x55.0
130VA-200VA
86.0
71.0
80.0
95.0
85.0
73.0
Φ5.0x8.0
C
71.5
57.0
80.0
95.0
85.0
88.0
Φ5.0x8.0
D
EI-96x32.0
55VA-80VA
96.0
80.0
57.0
72.0
55.0
82.0
Φ5.0x8.0
C
80.0
64.0
57.0
72.0
55.0
96.5
Φ5.0x8.0
D
EI-96x40.0
100VA-150VA
96.0
80.0
65.0
80.0
65.0
82.0
Φ5.0x8.0
C
80.0
64.0
65.0
80.0
65.0
96.5
Φ5.0x8.0
D
EI-96x45.0
130VA-180VA
96.0
80.0
70.0
85.0
70.0
82.0
Φ5.0x8.0
C
80.0
64.0
70.0
85.0
70.0
96.5
Φ5.0x8.0
D
EI-96x50.0
160VA-220VA
96.0
80.0
75.0
90.0
75.0
82.0
Φ5.0x8.0
C
80.0
64.0
75.0
90.0
75.0
96.5
Φ5.0x8.0
D
EI-96x56.0
200VA-250VA
96.0
80.0
82.0
97.0
82.0
82.0
Φ5.0x8.0
C
80.0
64.0
82.0
97.0
82.0
96.5
Φ5.0x8.0
D
EI-105x38.0
90.0VA-130VA
105.0
87.5
56.0
68.0
63.0
91.0
Φ5.0x10.0
C
87.5
70
56.0
68.0
63.0
105.0
Φ5.0x10.0
D
El-105x56.0
130VA-280VA
105.0
87.5
74.0
86.0
81.0
91.0
Φ5.0x10.0
C
87.5
70
74.0
86.0
81.0
105.0
Φ5.0x10.0
D
EI-114x50.0
200VA-260VA
114.0
95.0
78.0
94.0
90.0
96.0
Φ5.0x10.0
C
96.0
77.0
78.0
94.0
90.0
114.0
Φ5.0x10.0
D
El-114x60.0
250VA-360VA
114.0
95.0
88.0
104.0
110.0
96.0
Φ5.0x10.0
C
96.0
77.0
88.0
104.0
110.0
114.0
Φ5.0x10.0
D
EI-114x70.0
350VA-500VA
114.0
95.0
98.5
114.5
120.0
96.0
Φ5.0x10.0
C
96.0
77.0
98.5
114.5
120.0
114.0
Φ5.0x10.0
D
EI-133x50.0
250VA-360VA
133
111
75
100
105
111
Φ5.0x10.0
C
111
89
75
100
105
133
Φ5.0x10.0
D
EI-133x60.0
300VA-600VA
133
111
85
110
115
111
Φ5.0x10.0
C
111
89
85
110
115
133
Φ5.0x10.0
D
EI-133x70.0
500VA-800VA
133
111
95
120
120
111
Φ5.0x10.0
C
111
89
95
120
120
133
Φ5.0x10.0
D
EI-152x50.0
400VA-600VA
152
127
82
110
113
127
Φ6.0x15.0
C
127
102
82
110
113
152
Φ6.0x15.0
D
El-152x60.0
500VA-800VA
152
127
92
120
123
127
Φ6.0x15.0
C
127
102
92
120
123
152
Φ6.0x15.0
D
El-152x70.0
700VA-1000VA
152
127
102
130
133
127
Φ6.0x15.0
C
127
102
102
130
133
152
Φ6.0x15.0
D
El-162x50.0
500VA-700VA
162
135
84
113
115
135
Φ6.0x18.0
C
135
108
84
113
115
162
Φ6.0x18.0
D
El-162x60.0
700VA-900VA
162
135
94
123
125
135
Φ6.0x18.0
C
135
108
94
123
125
162
Φ6.0x18.0
D
El-162x70.0
800VA-1200VA
162
135
104
130
133
135
Φ6.0x18.0
C
135
108
104
130
133
162
Φ6.0x18.0
D
El-162x85.0
1000VA-1800VA
162
135
120
145
150
135
Φ6.0x18.0
C
135
108
120
145
150
162
Φ6.0x18.0
C
El-162x90.0
1600VA-2000VA
162
135
125
150
155
135
Φ6.0x18.0
D
135
108
125
150
155
162
Φ6.0x18.0
C

Please click bellow CONTACT US image for more information and quotation.
Flyback High Voltage PCB Electrical Current Power Transformer Ep10
Flyback High Voltage PCB Electrical Current Power Transformer Ep10
Flyback High Voltage PCB Electrical Current Power Transformer Ep10
Specification
Ⅰ. Specifications and Selection
1 Q: We need a 220V to 12V step down transformer. What specifications will be needed for production?
A: Please provide the following key parameters, the more detailed the better:
Input Voltage (Primary Voltage): For example, AC 220V. Is there an allowable fluctuation range (e.g. ±10%)?
Output Voltage and Current (Secondary Voltage & Current): For example, AC 12V, what current (A) or power (VA/W) is needed? If there are multiple output groups, please list the voltage current of each group.
Rated Power (Rated Power): The unit is VA (volt-ampere) or W (watt). This is one the most important parameters, determining the transformer's load-carrying capacity.
Frequency (Frequency): 50Hz or 60Hz?
Construction (Construction): Is it toroidal, EI type (frame-type), or R-type? Is there a special installation method (such vertical, horizontal, with a base, with a cover)?
Insulation Grade (Insulation Class): For example, Class A (105°C), Class (120°C), Class B (130°C), which is related to the transformer's heat resistance and lifespan.
 
2. Q: What is the difference between the power unit VA and W? How should I choose?
A: For purely resistive loads (such light bulbs, heating tubes), VA ≈ W. For inductive or capacitive loads (such as motors, appliances), W (real power) < VA ( power). To ensure safety, please select according to the apparent power (VA) of the load and leave a margin of 20%-30%. For example, 100W motor, it is recommended to choose a transformer of 120VA-150VA.
 
3. Q: Toroidal transformer or traditional EI transformer, which one should I choose?
A: The main differences are as follows, please choose according your priorities:
Characteristics
Toroidal transformer
EI Transformer
Efficiency
High (no air gap in magnetic circuit)
Lower
Leakage Magnetism/ Interference
Very little (magnetic field enclosed)
Larger
Volume and Weight
Smaller and lighter (for the same power)
Larger and heavier
Production Process
More complex
Mature and simple, easy to maintain
Application Scenarios
High-end audio, precision instruments occasions with high EMI requirements
General industrial equipment, conventional power supplies, cost-sensitive applications
Cost
Higher
Lower, cost-effective
4. Q: Is there a "shielding layer" in transformers? What is it used for?
A: Yes, you can specify the model needs a shielding layer. The shielding layer (usually a layer of copper foil) is located between the primary and secondary coils and is grounded, which can effectively suppress high- interference from the primary to the secondary, enhancing the equipment's ability to resist electromagnetic interference (EMI), which is essential for audio equipment and measuring instruments
5. Q: How to ensure the quality and service life of the transformer?
A: We ensure quality through the following aspects:
Material: new high-grade silicon steel sheets (such as H18, H14), 100% pure copper wire (not copper-clad aluminum), and materials of Class B (130°C) or above.
Process: Vacuum impregnation (VPI) process to ensure moisture resistance, shock absorption, dissipation, and insulation strength.
Testing: Conduct the following tests at 100% before leaving the factory: Dielectric strength test (Hi-Pot Test, such AC 3000V between primary and secondary), inter-winding test, load test, no-load current test, etc., and provide test reports.
II. Price and Delivery
7. Q: What is the price and what is the minimum order quantity (MOQ)?
A:Transformers are usually custom-made products, and the price and MOQ depend on your specific specifications and quantity.
Price factors: The higher the power, the higher the material requirements such as copper, silicon steel sheet prices), and the more complex the process (such as Toroidal, shielded), the higher the unit price.
MOQ For standard specifications, the MOQ may be lower (such as 100pcs). For fully custom specifications, since it requires mold opening (such as EI core mold) and sampling, the MOQ will be higher (such as 500-1000pcs). The larger the quantity, the lower the price.
8. Q: How long does the delivery take?
A: The delivery time also depends on the degree of customization and the quantity.
Standard products/small: Usually 10-15 working days.
New customization (sample confirmation required): It takes an additional 5-7 days for sample making and confirmation.
Large orders: It may take 15-30 days.
Please note that sharp fluctuations in raw material prices may also affect the delivery time.
Ⅲ.Service and Support Category
9. Q: Can samples be provided? How are samples charged?
A: Sure, we support sample for serious customers.
Sample Fee: Usually, sample fee is required, which can be refunded or deducted after placing a bulk order.
Sample Lead Time: Sample usually takes 3-5 days.
Confirmation: We will arrange bulk production only after you confirm that the sample is OK.
10. Q: What could be possible reasons if the transformer is broken? Do you provide warranty?
A: Common damage reasons:
Overload: The load power exceeds the transformer's rated power.
Short circuit: Short circuit at the output end causes a momentary large current to burn out.
Harsh Environment: Working in a high-temperature, humid environment for a long time to insulation aging.
We usually provide a 1-year warranty period. If it is a quality issue of the product, we will repair or replace it for free.

Please click bellow CONTACT US image for more information and quotation.
Flyback High Voltage PCB Electrical Current Power Transformer Ep10
Flyback High Voltage PCB Electrical Current Power Transformer Ep10
Flyback High Voltage PCB Electrical Current Power Transformer Ep10
Flyback High Voltage PCB Electrical Current Power Transformer Ep10
Flyback High Voltage PCB Electrical Current Power Transformer Ep10

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASI2431790". Items marked "verified" are certified.

Watch Video
Watch Video
Hangzhou Udwells Technology Co., Ltd.
Hangzhou Udwells Technology Co., Ltd.
Hangzhou Udwells Technology Co., Ltd.
Hangzhou Udwells Technology Co., Ltd.
Hangzhou Udwells Technology Co., Ltd.
Hangzhou Udwells Technology Co., Ltd.
Hangzhou Udwells Technology Co., Ltd.
Hangzhou Udwells Technology Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Room 2412, Building 9, Ideal Yintai City, Nanyuan Street, Linping District, Hangzhou, Zhejiang, China
verified Plant Area
80 square meters
verified Number of Employees
3
verified Registered Capital
500,000 RMB
verified Terms of Payment
T/T
verified International Commercial Terms(Incoterms)
FOB, EXW, CIF
verified Average Lead Time
Peak Season Lead Time: within 15 workdays, one month
Off Season Lead Time: within 15 workdays, one month
verified Nearest Port
Shanghai Port, Ningbo Port
verified Minimum Order Quantity
2000 Pcs
verified Supply Chain Partners
5

Our Production Capability & Technical Expertise

verified Main Products
LED Driver, Transformer
verified Production Lines
27
verified Production Machines
PCBA Line, Assembling Line, Winding Machine
verified QA/QC inspectors
1 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instruction but no written records
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Flexible customization, Minor Customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
1 people
verified Traceability of Raw Materials
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2021-11-11
verified Export Year
3 Years
verified Main Markets
Europe
verified Repeat Buyers Choice
80%~100%
verified Number of Foreign Trading Staff
3
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
Yes

Our Certifications, Standards & Industry Recognition

verified Cooperated with Fortune 500
No

FAQ

What specifications are needed for a 220V to 12V transformer?
Please provide Input Voltage with fluctuation range, Output Voltage and Current, Rated Power (VA/W), Frequency (50Hz/60Hz), Construction type (Toroidal/EI/R), Installation method, and Insulation Grade.
Which should I choose: Toroidal or EI transformer?
Toroidal offers high efficiency and low interference but is larger and costlier. EI is smaller, lighter, cheaper, and easier to maintain, suitable for general industrial use.
Is there a shielding layer in transformers?
Yes, a copper foil shielding layer can be added between primary and secondary coils to suppress high interference and enhance EMI resistance.
How do you ensure quality and service life?
We use high-grade silicon steel and pure copper, apply VPI process, and conduct 100% testing including Hi-Pot, inter-winding, and load tests.
What is the price and MOQ?
Price depends on power and complexity. MOQ is lower for standard specs (e.g., 100pcs) and higher for custom molds (e.g., 500-1000pcs). Larger quantities reduce unit price.
How long does delivery take?
Standard products take 10-15 working days. New customizations require an additional 5-7 days for samples. Large orders may take 15-30 days.
Can samples be provided and how are they charged?
Samples are available for serious customers. A fee is usually required but can be refunded or deducted after a bulk order. Lead time is 3-5 days.
What causes transformer failure and is there a warranty?
Failures are caused by overload, short circuits, or harsh environments. We provide a 1-year warranty covering free repair or replacement for quality issues.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now